Home > Failed To > Failed To Unconfigure Scsi Device I/o Error

Failed To Unconfigure Scsi Device I/o Error

To continue the configure operation, either remove the unsupported device

Contents

and will keep posting here the questions. The dynamic reconfiguration software cannot detect all cases where a system hang might result. c0t1d0 /[email protected],4000/[email protected]/[email protected],0 2. cfgadm command does list the replaced drive c1t0d0 cfgadm -f -c configure c1::dsk/c1t0d0 cfgadm: Hardware specific failure: failed to configure SCSI device: I/O error c1::sd3 disk connected unconfigured unknown Solved! Check This Out

Force Archer: The sniper that fires deadly force s... To regain access to the devices which were not unconfigured, the board must be completely unconfigured and then reconfigured. To identify "c#::dsk/c#t#d0", we need to execute the following command in advance if you are not sure. Cannot Configure Either CPU0 or CPU1 While the Other Is Configured Before you try to configure either CPU0 or CPU1, make sure that the other CPU is unconfigured. useful source

Cfgadm Force Unconfigure

Tech notes,game notes, unix notes and the likes. matty on May 2, 2005 | Filed Under Solaris Volume Manager 10 Comments Vinay on March 28th, 2006 In the method descirbed above, you are deleting the replicas on this disk Run the 'cfgadm' command to remove the failed disk.cfgadm -c unconfigure c#::dsk/c#t#d#NOTE: if the message "Hardware specific failure: failed to unconfigure SCSI device: I/O error" appears, check to make sure that Email check failed, please try again Sorry, your blog cannot share posts by email.

  1. Then run "prtvtoc" to format the replacement disk to look like the good mirror disk.
  2. prompt to proceed.
  3. Configure a SCSI controller. # cfgadm -c configure c1 Verify that the SCSI controller is configured. # cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c0::dsk/c0t0d0 disk
  4. Force Blader: Swordsman whose blade flares with th...

The second time you run the cfgadm command, it will take a minute to re-scan your disks, so be patient. How to Display Information About SCSI Devices The following procedure uses SCSI controllers c0 and c1 and the devices that are attached to them in the examples of the type of How to Configure a SCSI Controller The following procedure uses SCSI controller c1 in the example of configuring a SCSI controller. Cfgadm: Configuration Operation Not Supported If this is still not successful then you can try the Infodoc as last resort, but otherwise it appears you may need to reboot to resolve the issue this time (and

Unconfigure Operation Failure An unconfigure operation for a CPU/Memory board or an I/O board can fail if the system is not in a correct state before you begin the operation. The HDD is ready to remove when both paths show unconfigured. Note : The VTOC (volume table of contents) on the root disk and root mirror must be the same. why not find out more cfgadm -c unconfigure c#::dsk/c#t#d# NOTE: if the message "Hardware specific failure: failed to unconfigure SCSI device: I/O error" appears, check to make sure that you cleared all replicas and metadevices from

The author will not be held liable for any problems that result from the information provided here.

Copyright Cfgadm: Insufficient Condition Anyone care to chime in? please advice….thanks in advance… Leave a Comment Username (required) : Email (required) : Web Site : Comment : Search Search for: Categories AIX Debugging (1) AIX Package Management (2) Apache (29) More articles » Applications » Fixing NIC Name in Cloned VMWare Linux Machines A suspected bug with certain versions of VMware ESX causes cloned Linux VMs to obtain a sequentially-number NIC.

Cfgadm Unconfigure Disk

Don't forget to substitute the correct name for the meta devices on your system: Shell for i in d20 d21 d23 d26 ; do /usr/sbin/metaclear $i ; done 1 for i http://www.shrubbery.net/solaris9ab/SUNWdhshw/806-6783-10/trouble.html If a device on the board is busy, the system logs a message such as the following after an attempt to unconfigure: cfgadm: Hardware specific failure: unconfigure N0.IB6: Device busy: /[email protected],0/[email protected],700000/[email protected]/SUNW,[email protected]/[email protected],0 Cfgadm Force Unconfigure You must unconfigure both ports. Cfgadm Command In Solaris The board must be in the unconfigured state before you try to reconfigure this board.

Continue (yes/no)? his comment is here Display information about attachment points on the system. # cfgadm -l Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c1 scsi-bus connected configured unknown In this example, c0 and Run metareplace to enable and resync the new disk. Run 'format' or 'prtvtoc' to put the desired partition table on the new disk7. Cfgadm: Attachment Point Not Found

rather than deleting config details from the dg, remove disk for replacement: - run: vxdiskadm -> option 4 (Remove a disk for replacement) [follow prompts] - then the OS steps (cfgadm c0t0d0 /[email protected],4000/[email protected]/[email protected],0 1. If there are any replicas on this disk, remove them using:metadb -d c#t#d#s#Verify there are no existing replicas left on the disk, by running:metadb grep c#t#d#3. http://indywebshop.com/failed-to/failed-to-create-device-node-i-o-error.php If you are seeingI/O errors instead, you can exclude the the device(s) from dmp.The OS believes that something is still using this disk. 1)Check to verify if there are still

All rights reserved. Luxadm Forcelip CPUs on a Board Must Be Configured Before Memory Before configuring memory, all CPUs on the system board must be configured. http://www.razerzone.com/gaming-keyboards-keypads/razer-mechanical-keyboard-case-ipad-pro More articles » Recent Posts While You Were Offline: People on Twitter Don’t Think Women Should Vote Huawei Brazil announces new leadership Shirley Jackson Is Finally Getting the Appreciation She

The system logs a message such as the following: cfgadm: Hardware specific failure: configure N0.IB6: Unsafe driver present: To continue the configure operation, either remove the unsupported device

The disk c0t2d0 is failing and needs to be replaced.Here is the 'format' display before the submirror disk replacement: format AVAILABLE DISK SELECTIONS: 0. Symantec Connect User-to-user forums, blogs, videos, and other community resources on Symantec Connect. cfgadm -c unconfigure c#::dsk/c#t#d#4. Devfsadm mendhak My laptop shows a blue screen message, saying that the HDD has failed.

metadevadm -u c#t#d# NOTE: If you get the message "Open of /dev/dsk/c#t#d#s0 failed", you can safely ignore the message (this is a known bug pending a fix). Example of swap device of alternate boot disk is c1t1d0s1: # dumpadm -d /dev/dsk/c1t1d0s1 2. format [ the steps to create a valid partition table have been left out for brevity ]We run 'metadevadm' to update the SVM database with the new DevID information. navigate here Bridged NICs.

Things every Unix sysadmin needs to know. Become superuser. Remove the SVM database from board-resident partitions. Error Message cfgadm: Component system is busy, try again: failed to offline: device-path Resource Information ------------------ -------------------------- /dev/dsk/device-name dump device (swap) Cause You attempted to remove or replace a dump device

However, you should consult your hardware documentation to confirm whether hot-plugging is supported for your SCSI devices. so SUN replaced the disk and i executed cfgadm -al , devfsadm -Cv, vxdctl enable but not able to see the new disk so i tried many commands but no luck c0t5000CCA025048FD0d0 <HITACHI-H106060SDSUN600G-A2B0 cyl 64986 alt 2 hd 27 sec 668> solaris          /scsi_vhci/[email protected]           /dev/chassis/SPARC_M5-32.AK00056255//SYS/IOU1/HDD0/disk ...The selected drive should have disappeared from the output when compared to the output before the unconfigure operation. Do I just need to buy a new computer or is there a way to fix this?

Note: If the submirror was something other than a simple one-slice concat device, the metainit command will be different than shown here. Cannot Unconfigure a Board Whose Memory Is Interleaved Across Boards If you try to unconfigure a system board whose memory is interleaved across system boards, the system displays an error message Note: the DevID information at the bottom. Volume management, logical volumes, HA filesystems.

The replacement device should be of the same type and at the same address (target and lun) as the device to be removed.